Subscribe to VETERINARY PRACTICE NEWS   SUBSCRIBER SERVICES   
VPN Logo   
 Home   About Us   Contact Us
 

Trephination Surgery Huntington WV

A needle aspiration biopsy is safer and less traumatic than an open surgical biopsy, and significant complications are usually rare, depending on the body site. It gets more cells and less blood.

Equine Medical Ctr
(740) 867-0066
764 County Road 31
Chesapeake, OH

Data Provided by:
Ayers Animal Hospital
(304) 529-6049
1514 Norway Ave
Huntington, WV

Data Provided by:
Barboursville Veterinary
(304) 736-8939
6310 Farmdale Rd
Barboursville, WV

Data Provided by:
Help For Animals Inc
(304) 736-8555
1 Humane Way
Barboursville, WV

Data Provided by:
Martin Veterinary Clinic
(606) 324-8036
1426 Grandview Dr
Ashland, KY

Data Provided by:
Tri-State Veterinary Hospital
(304) 525-8387
6474 Merritts Crk Rd
Huntington, WV
 
Proctorville Animal Clinic
(740) 886-9424
6129 County Road 107
Proctorville, OH

Data Provided by:
Olson Animal Hospital
(304) 736-1677
5980 Us Route 60 E
Barboursville, WV

Data Provided by:
Tambling, Fred R, Dvm - Barboursville Veterinary
(304) 736-8939
6310 Farmdale Rd
Barboursville, WV

Data Provided by:
Advanced Veterinary Svc
(606) 324-2984
3101 13th St
Ashland, KY

Data Provided by:
Data Provided by:

Trephination: Get More Cells and Less Blood

Sure it’s an old article 1 , but it explains a very practical and simple way to increase the yield of fine needle aspirates.

Once supplies are gathered (see box), the needle is connected to the IV extension set, which is connected to the air-filled syringe. Cool people place the IV extension set around their neck rather than letting it dangle or be in the way.

Supplies Needed:

  • Glass slides.
  • 22 G needles, short for superficial masses, long for deeper masses.
  • IV extension set (14 inches are enough).
  • 12 ml syringe containing at least 5 ml of air.

Note : The IV extension set and the syringe can be reused multiple times since they should not become contaminated.

The patient is sedated if needed, and the biopsy site is scrubbed aseptically. The needle is held like a pen in one hand, and the mass is held in the other hand.

The needle is placed inside the mass and moved quickly back and forth about eight to 10 times.

The needle is then removed from the mass and its contents are placed on the glass slides by pushing the plunger of the air-filled syringe. A classic smear is then made and air-dried using a blow dryer.

The process can be repeated as needed, typically three to five times, in other areas of the mass.

It is important to perform all steps quickly to avoid hemodilution of the sample or coagulation, which is trauma-induced.

Advantages of this system is a higher cellular yield, less hemodilution and the possibility of re...

Copyright 2009 BowTie Inc.